Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 5342, 2024 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-38438563

RESUMO

The purpose of the present study was to evaluate the in vitro activity of tedizolid against several clinically significant species of Nocardia by comparing with that of linezolid. A total of 286 isolates of Nocardia species, including 236 clinical isolates recovered from patients in Japan and 50 strains (43 species) purchased from NITE Biological Resource Center, were studied. Antimicrobial susceptibility testing was performed using the broth microdilution method. For the 286 Nocardia isolates, the minimal inhibitory concentration (MIC)50 and MIC90 values of tedizolid were 0.25 and 0.5 µg/ml, and those of linezolid were 2 and 2 µg/ml, respectively. The distribution of the linezolid/tedizolid ratios (MICs of linezolid/MICs of tedizolid) showed that tedizolid had four- to eight-fold higher activity than linezolid in 96.1% (275/286) of Nocardia isolates. Both the tedizolid and linezolid MIC90 values for Nocardia brasiliensis were two-fold higher than those for the other Nocardia species. Both tedizolid and linezolid had low MIC values, 0.25-1 µg/ml and 0.5-4 µg/ml, respectively, even against nine isolates (five species) that were resistant to trimethoprim/sulfamethoxazole. One Nocardia sputorum isolate showed reduced susceptibility to tedizolid (4 µg/ml). Bioinformatics analysis suggests different resistance mechanisms than the oxazolidinone resistance seen in enterococci and staphylococci.


Assuntos
Nocardia , Oxazolidinonas , Humanos , Linezolida/farmacologia , Tetrazóis
2.
Sci Rep ; 11(1): 16742, 2021 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-34408177

RESUMO

The aims of the present study were to profile the antimicrobial susceptibility patterns of a diverse range of Nocardia species isolated in Japan, and to determine the ability of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) for species/complex identification. Identification of 153 clinical isolates was performed by full-length 16S rRNA gene sequencing as a reference method to evaluate the usefulness of MALDI-TOF MS identification. Antimicrobial susceptibility testing (AST) for 14 antibiotics was performed using the broth microdilution method against 146 of the isolates. Among the total 153 clinical isolates, Nocardia farcinica complex (25%) was the most common species, followed by Nocardia cyriacigeorgica (18%), Nocardia brasiliensis (9%), Nocardia nova (8%), and Nocardia otitidiscaviarum (7%). Among 150 isolates identified to the species/complex level by 16S rRNA gene sequencing, MALDI-TOF MS with the use of a supplemental Nocardia library (JMLD library ver.ML01) correctly identified 97.3% (n = 146) to the species/complex level and 1.3% (n = 2) to the genus level. Among the 146 Nocardia isolates that underwent AST, the susceptibilities were 100% to linezolid, 96% to amikacin, 94% to trimethoprim-sulfamethoxazole, and 76% to imipenem. None of the trimethoprim-sulfamethoxazole-resistant isolates carried either plasmid-mediated sulfonamide-resistant genes (sul1, sul2) or trimethoprim-resistant genes (dfrA).


Assuntos
Farmacorresistência Bacteriana/genética , Genes Bacterianos , Nocardia , Plasmídeos/genética , RNA Bacteriano/genética , RNA Ribossômico 16S/genética , Humanos , Japão , Nocardia/genética , Nocardia/isolamento & purificação
3.
Fukushima J Med Sci ; 66(2): 103-112, 2020 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-32713872

RESUMO

In hospital microbial laboratories, morphological and biochemical analyses are performed to identify pathogenic microbes;however, these procedures lack rapidity and accuracy. Recently, Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) has been clinically utilized, and is expected to enable rapid and accurate microbial identification. We aimed to validate two MALDI-TOF MS devices available in Japan: the VITEK-MS (BioMérieux) and the Microflex LT (Bruker Daltonics). Clinically isolated bacteria, 100 samples in all, detected in blood cultures but incompletely identified by conventional procedures, were reanalyzed using the two devices. The VITEK-MS and Microflex LT, respectively, identified 49% (49/100) and 80% (80/100) of the tested bacteria at the species level, as well as 96% (96/100) and 95% (95/100) at the genus level. Among those reidentified strains, 26% (26/100) at the species level and 88% (88/100) at the genus level were concordant with each other, though three strains were unmatched. Moreover, four bacterial strains were unable to be identified using the VITEK-MS, versus five using the Microflex LT. MALDI-TOF MS devices can provide more rapid and accurate bacterial identification than ever before;however, the characteristics of each system were slightly different;therefore, it is necessary to understand the difference in performance of MALDI-TOF MS models.


Assuntos
Bactérias/isolamento & purificação , Hemocultura , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...